• 1920x300 nybjtp

Kineski proizvođač CJM3-250 225A 35kA/25kA MCCB prekidač u lijevanom kućištu

Kratki opis:

Primjena

Prekidač s lijevanim kućištem serije CJMM1 (u daljnjem tekstu prekidač) primjenjiv je za AC 50/60HZ distribucijski krug električne energije s nazivnim naponom izolacije od 800V, nazivnim radnim naponom od 690V i nazivnom radnom strujom od 10A do 630A. Koristi se za distribuciju energije i sprječavanje oštećenja krugova i opreme za napajanje zbog preopterećenja, kratkog spoja, podnapona i drugih kvarova. Također se koristi za rijetko pokretanje motora, kao i zaštitu od preopterećenja, kratkog spoja i podnapona. Ovaj prekidač ima prednosti malog volumena, visoke prekidne moći, kratkog luka (ili bez luka) itd., može biti opremljen priborom poput alarmnog kontakta, okidača za prekid, pomoćnog kontakta itd., idealan je proizvod za korisnika. Prekidač diferencijalne struje može se ugraditi vertikalno (vertikalna ugradnja) ili horizontalno (horizontalna ugradnja). Proizvod je u skladu sa standardima IEC60947-2 i Gb140482.


Detalji proizvoda

Oznake proizvoda

Model proizvoda

CJ:Kod poduzeća
M: Prekidač s lijevanim kućištem
1: Broj dizajna
□: Nazivna struja okvira
□:Kôd karakteristike prekidne moći/S označava standardni tip (S se može izostaviti)H označava viši tip

Napomena: Postoje četiri vrste neutralnog pola (N pol) za četverofazni proizvod. Neutralni pol tipa A nije opremljen elementom za zaštitu od prekomjerne struje, uvijek je uključen i ne uključuje se ili isključuje zajedno s ostala tri pola.
Neutralni pol tipa B nije opremljen elementom za zaštitu od prekomjerne struje i uključuje se ili isključuje zajedno s ostala tri pola (neutralni pol se uključuje prije isključivanja). Neutralni pol tipa C opremljen je elementom za zaštitu od prekomjerne struje i uključuje se ili isključuje zajedno s ostala tri pola (neutralni pol se uključuje prije isključivanja). Neutralni pol tipa D opremljen je elementom za zaštitu od prekomjerne struje, uvijek je uključen i ne uključuje se ili isključuje zajedno s ostala tri pola.

Tablica 1

Naziv pribora Elektroničko otpuštanje Oslobađanje spoja
Pomoćni kontakt, podnaponski okidač, alarmni kontakt 287 378
Dva pomoćna seta kontakata, kontakt alarma 268 368
Isključivač, alarmni kontakt, pomoćni kontakt 238 348
Otpuštanje podnapona, kontakt alarma 248 338
Pomoćni kontakt alarmni kontakt 228 328
Kontakt alarma za okidanje napona 218 318
Pomoćni kontakt podnaponskog okidača 270 370
Dva pomoćna seta kontakata 260 360
Isključujući relejni relej podnaponskog releja 250 350
Pomoćni kontakt za okidanje napona 240 340
Otpuštanje podnapona 230 330
Pomoćni kontakt 220 320
Isključivač 210 310
Kontakt alarma 208 308
Bez dodatne opreme 200 300

Klasifikacija

  • Prema prekidnoj moći: a standardni tip (tip S) b tip s većom prekidnom moći (tip H)
  • Prema načinu povezivanja: a priključak prednje ploče, b priključak stražnje ploče, c vrsta utikača
  • Prema načinu rada: a izravno upravljanje ručkom, b upravljanje rotacijskom ručkom, c električno upravljanje
  • Po broju polova: 1P, 2P, 3P, 4P
  • Pomoću pribora: kontakt alarma, pomoćni kontakt, okidač napona, okidač podnapona

Normalno stanje usluge

  • Nadmorska visina mjesta ugradnje ne smije prelaziti 2000 m
  • Temperatura okolnog zraka
  • Temperatura okolnog zraka ne smije prelaziti +40℃
  • Prosječna vrijednost ne smije prelaziti +35 ℃ unutar 24 sata
  • Temperatura okolnog zraka ne smije biti niža od -5 ℃
  • Atmosferski uvjeti:
  • 1. Referentna vlažnost zraka ovdje ne smije prelaziti 50% pri najvišoj temperaturi od +40 ℃, a može biti i viša pri nižim temperaturama. Kada prosječna najniža temperatura u najvlažnijem mjesecu ne prelazi 25 ℃ može biti 90%, mora se uzeti u obzir kondenzacija na površini proizvoda zbog promjene temperature.
  • Razina zagađenja je 3. klase

Glavni tehnički parametar

1 Nazivna vrijednost prekidača
Model Imax (A) Specifikacije (A) Nazivni radni napon (V) Nazivni napon izolacije (V) Icu (kA) Ics (kA) Broj polova (P) Udaljenost luka (mm)
CJMM1-63S 63 6, 10, 16, 20
25, 32, 40,
50,63
400 500 10* 5* 3 ≤50
CJMM1-63H 63 400 500 15* 10* 3,4
CJMM1-100S 100 16, 20, 25, 32
40, 50, 63,
80.100
690 800 35/10 22/5 3 ≤50
CJMM1-100H 100 400 800 50 35 2, 3, 4
CJMM1-225S 225 100.125,
160, 180,
200.225
690 800 35/10 25/5 3 ≤50
CJMM1-225H 225 400 800 50 35 2, 3, 4
CJMM1-400S 400 225.250,
315.350,
400
690 800 50/15 35/8 3,4 ≤100
CJMM1-400H 400 400 800 65 35 3
CJMM1-630S 630 400.500,
630
690 800 50/15 35/8 3,4 ≤100
CJMM1-630H 630 400 800 65 45 3
Napomena: Kada su parametri ispitivanja za 400V, 6A bez okidača grijanja
2 Karakteristika inverznog vremenskog prekida kada je svaki pol nadstrujnog okidača za distribuciju energije uključen istovremeno
Stavka ispitivanja Struja (I/In) Područje vremena testiranja Početno stanje
Struja neisključivanja 1,05 In 2 sata (n>63A), 1 sat (n<63A) Hladno stanje
Struja okidanja 1,3 In 2 sata (n>63A), 1 sat (n<63A) Odmah nastavite
nakon testa br. 1
3 Karakteristika inverznog prekidanja vremena kada svaki pol preopterećenja
istovremeno se uključuje strujno oslobađanje za zaštitu motora.
Postavka Trenutno Konvencionalno vrijeme Početno stanje Bilješka
1,0 inča >2 sata Hladno stanje
1,2 inča ≤2 sata Nastavljeno odmah nakon testa br. 1
1,5 inča ≤4 min Hladno stanje 10≤In≤225
≤8 min Hladno stanje 225≤In≤630
7,2 inča 4s≤T≤10s Hladno stanje 10≤In≤225
6s≤T≤20s Hladno stanje 225≤In≤630
4 Karakteristika trenutnog djelovanja prekidača za distribuciju energije mora biti postavljena na 10in+20%, a prekidača za zaštitu motora na 12ln±20%

Veličina instalacije okvira

CJMM1-63, 100, 225, Dimenzije gabarita i ugradnje (priključak prednje ploče)

Veličine (mm) Kod modela
CJMM1-63S CJMM1-63H CJMM1-63S CJMM1-100S CJMM1-100H CJMM1-225S CJMM1-225
Veličine obrisa C 85,0 85,0 88,0 88,0 102,0 102,0
E 50,0 50,0 51,0 51,0 60,0 52,0
F 23,0 23,0 23,0 22,5 25,0 23,5
G 14,0 14,0 17,5 17,5 17,0 17,0
G1 6,5 6,5 6,5 6,5 11,5 11,5
H 73,0 81,0 68,0 86,0 88,0 103,0
H1 90,0 98,5 86,0 104,0 110,0 127,0
H2 18,5 27,0 24,0 24,0 24,0 24,0
H3 4.0 4,5 4.0 4.0 4.0 4.0
H4 7.0 7.0 7.0 7.0 5.0 5.0
L 135,0 135,0 150,0 150,0 165,0 165,0
L1 170,0 173,0 225,0 225,0 360,0 360,0
L2 117,0 117,0 136,0 136,0 144,0 144,0
W 78,0 78,0 91,0 91,0 106,0 106,0
W1 25,0 25,0 30,0 30,0 35,0 35,0
W2 - 100,0 - 120,0 - 142,0
W3 - - 65,0 65,0 75,0 75,0
Veličine instalacija A 25,0 25,0 30,0 30,0 35,0 35,0
B 117,0 117,0 128,0 128,0 125,0 125,0
od 3,5 3,5 4,5 4,5 5,5 5,5

CJMM1-400,630,800,Grafične i instalacijske veličine (priključak prednje ploče)

Veličine (mm) Kod modela
CJMM1-400S CJMM1-630S
Veličine obrisa C 127 134
C1 173 184
E 89 89
F 65 65
G 26 29
G1 13,5 14
H 107 111
H1 150 162
H2 39 44
H3 6 6,5
H4 5 7,5
H5 4,5 4,5
L 257 271
L1 465 475
L2 225 234
W 150 183
W1 48 58
W2 198 240
A 44 58
Veličine instalacija A1 48 58
B 194 200
Od 8 7

Dijagram izreza za spajanje stražnje ploče - utikač

Veličine (mm) Kod modela
CJMM1-63S
CJMM1-63H
CJMM1-100S
CJMM1-100H
CJMM1-225S
CJMM1-225H
CJMM1-400S CJMM1-400H CJMM1-630S
CJMM1-630H
Veličine utikača za priključak stražnje ploče A 25 30 35 44 44 58
od 3,5 4,5*6
duboka rupa
3.3 7 7 7
od1 - - - 12,5 12,5 16,5
od2 6 8 8 8,5 9 8,5
oD 8 24 26 31 33 37
oD1 8 16 20 33 37 37
H6 44 68 66 60 65 65
H7 66 108 110 120 120 125
H8 28 51 51 61 60 60
H9 38 65,5 72 - 83,5 93
H10 44 78 91 99 106,5 112
H11 8,5 17,5 17,5 22 21 21
L2 117 136 144 225 225 234
L3 117 108 124 194 194 200
L4 97 95 9 165 163 165
L5 138 180 190 285 285 302
L6 80 95 110 145 155 185
M M6 M8 M10 - - -
K 50,2 60 70 60 60 100
J 60,7 62 54 129 129 123
M1 M5 M8 M8 M10 M10 M12
W1 25 35 35 44 44 58

Što je MCCB?

Prekidači s lijevanim kućištem su električni zaštitni uređaji koji su dizajnirani za zaštitu električnog kruga od prekomjerne struje. Ova prekomjerna struja može biti uzrokovana preopterećenjem ili kratkim spojem. Prekidači s lijevanim kućištem mogu se koristiti u širokom rasponu napona i frekvencija s definiranom donjom i gornjom granicom podesivih postavki isključenja. Osim mehanizama za isključivanje, kompaktni prekidači mogu se koristiti i kao ručni prekidači za isključivanje u slučaju nužde ili održavanja. Kompaktni prekidači su standardizirani i testirani na prekomjernu struju, prenaponski udar i zaštitu od kvara kako bi se osigurao siguran rad u svim okruženjima i primjenama. Učinkovito djeluju kao prekidač za resetiranje električnog kruga kako bi isključili napajanje i smanjili štetu uzrokovanu preopterećenjem kruga, spojem na zemlji, kratkim spojevima ili kada struja premaši ograničenje struje.

 

Važnost lijevanog kućištaPrekidač strujnog krugau osiguravanju električne sigurnosti

U današnjem modernom svijetu, električna energija važan je dio našeg svakodnevnog života. Od opskrbe energijom naših domova do pokretanja industrijskih strojeva, osiguranje sigurnosti i pouzdanosti električnih sustava je ključno. Prekidač u lijevanom kućištu (MCCB) ključna je komponenta koja igra važnu ulogu. U ovom blogu istražit ćemo važnost MCCB-a u osiguravanju električne sigurnosti.

MCCB je električni zaštitni uređaj dizajniran za zaštitu strujnih krugova i opreme od preopterećenja i kratkih spojeva. Uobičajeno se koristi u stambenim, komercijalnim i industrijskim primjenama kako bi se spriječilo oštećenje električnih sustava i, što je još važnije, smanjio rizik od električnih požara.

Jedna od glavnih funkcija kompaktnog prekidača (MCCB) je prekid protoka struje u slučaju preopterećenja ili kratkog spoja. To je ključno za sprječavanje pregrijavanja žica i komponenti, što može dovesti do požara i katastrofalnih oštećenja. Isključivanjem strujnih krugova i prekidom napajanja, kompaktni prekidači pomažu u izbjegavanju potencijalnih opasnosti te štite ljude i imovinu.

Osim toga, kompaktni prekidač (MCCB) pruža određenu razinu praktičnosti i fleksibilnosti električnim sustavima. Mogu se lako resetirati nakon kvara, što omogućuje brzo vraćanje napajanja bez potrebe za zamjenom bilo kakvih komponenti. To ne samo da štedi vrijeme i trud, već i minimizira zastoje i poremećaje u svakodnevnom radu.

Osim što sprječavaju električne opasnosti, prekidači s lijevanim kućištem pomažu u poboljšanju ukupne učinkovitosti i pouzdanosti električnih sustava. Štiteći od preopterećenja i kratkih spojeva, pomažu u održavanju integriteta električne opreme i produžuju njezin vijek trajanja. To zauzvrat smanjuje potrebu za skupim popravcima i zamjenama, dugoročno štedeći vrijeme i novac.

Vrijedi napomenuti da nisu svi kompaktni prekidači isti. Prilikom odabira kompaktnog prekidača za određenu primjenu, ključno je uzeti u obzir čimbenike kao što su nazivna struja, prekidna moć i radni napon. Ove specifikacije treba pažljivo uskladiti sa zahtjevima električnog sustava kako bi se osigurala odgovarajuća zaštita i performanse.

Osim toga, redovito održavanje i testiranje kompaktnog prekidača (MCCB) ključno je za osiguranje njegove kontinuirane učinkovitosti. Redoviti pregledi i testovi mogu pomoći u prepoznavanju potencijalnih problema ili habanja kako bi se po potrebi mogli izvršiti popravci ili zamjene.

Ukratko, prekidači s lijevanim kućištem igraju vitalnu ulogu u osiguravanju električne sigurnosti i pouzdanosti. Štiteći od preopterećenja i kratkih spojeva, pomažu u sprječavanju električnih opasnosti i smanjuju rizik od požara. Osim toga, pomažu u povećanju učinkovitosti i dugovječnosti električnih sustava, što ih čini neizostavnom komponentom u modernim električnim instalacijama. Ulaganje u kvalitetne kompaktne prekidače (MCCB) i osiguravanje njihovog pravilnog održavanja ključno je za zaštitu ljudi i imovine od opasnosti električnih kvarova.


  • Prethodno:
  • Sljedeći:

  • Napišite svoju poruku ovdje i pošaljite nam je